| FF Version |
 |
 |
| extra fixing points |
| |
 |
Attention:
All the images, schemes and photos are property of Coprel s.a.s. and are under Copyright. |
|
|
 |
| Cross Flow Fans |
| TF/FF Series |
 |
|
 |
|
 |
| Technical Specifications: |
 |
Single phase, 2 shaded poles, impedance protected motor, built complying “CE” standards, with self-lubricating and self-aligning sleeve bearings, with big oil reservoir; |
 |
 |
motor with “F” insulation class ( 155°C); |
 |
 |
suitable for continuous duty with room temperature between -10°C and + 60°C; |
 |
 |
electric supply by 6,3x0,8mm male faston-type connectors, directly fixed on coil; |
 |
 |
ø 60mm fan blade with curved forward pales, made with strengthening intermediate discs, with constant thickness; |
 |
 |
housing made of zincoated metal plate. |
|
| |
| On Request: |
 |
motor with “H” insulation class ( 180°C); |
 |
 |
operating voltages between 12V and 400V 50/60Hz; |
 |
 |
version with double voltage and/or double rotation speed; |
 |
 |
electric supply with flying cables of various lengths; |
 |
 |
protection against dust and/or humidity; |
 |
 |
coil bobbin with “IP56” protection class; |
 |
 |
thermal protector and/or thermal cut off protection; |
 |
 |
housing made with superficial cataphoresis treatment; |
 |
 |
“HT” version for functioning between -30°C and + 100°C; |
 |
 |
built complying UL-CSA standards; |
 |
 |
“BB version” with two 626ZZ ball bearings type on the motor; |
 |
 |
“BBBLV” version with two 626ZZ ball bearings type on the motor and 624ZZ ball bearings type on the fan wheel side; |
 |
 |
AISI steel driving shaft 420 with milled plane. |
|
 |
| Motor position: |
 |
|
 |
| ID code : |
| (point the mouse on the code to visualize the details) |
| |
|
 |
(*) impregnated versions:
IV Version: impregnated coil bobbin through immersion in epoxydic varnish (classic impregnation of stators);
PRN Version: coil bobbin spread with black epoxydic resin, the bobbin is protected by a visible layer of resin;
IM Version: the coil bobbin is impregnated through immersion in epoxydic varnish with silicon put in the contacts zone at the end of the winding and 3 cores cable, the bobbin is covered by a nylon cap. The coil bobbin is not submerged in the resin, but well visible, it should be necessary to pay attention and to place the motor in a way that the open part of the cap will be directed downward in order to prevent that it could fill up of humidity;
INC Version: coil bobbin in “IP56”, the bobbin is completely submerged in the epoxydic resin. |
 |
 |
| TF Dimensions: |
 |
 |
 |
| TF Versions: |
 |
| Series |
Motor |
Dimensions |
Input power W |
Input current A |
Free air RPM |
Free air flow rate |
Static pressure PA |
| A |
B |
C |
D |
H |
I |
| TF90/15 |
15-1 |
156 |
64 |
94 |
104 |
15 |
53.5 |
18 |
0,140 |
1900 |
60 |
60 |
| TF90/20 |
20-1 |
162 |
64 |
94 |
104 |
20 |
58.5 |
23 |
0,150 |
2400 |
80 |
62 |
| TF120/15 |
15-1 |
186 |
94 |
124 |
134 |
15 |
53.5 |
19 |
0,160 |
1600 |
85 |
58 |
| TF120/20 |
20-1 |
191 |
94 |
124 |
134 |
20 |
58.5 |
24 |
0,170 |
2150 |
110 |
62 |
| TF180/15 |
15-1 |
246 |
154 |
184 |
194 |
15 |
53.5 |
19 |
0,150 |
1300 |
100 |
55 |
| TF180/20 |
20-1 |
251 |
154 |
184 |
194 |
20 |
58.5 |
25 |
0,180 |
1600 |
125 |
60 |
| TF180/30 |
30-1 |
261 |
154 |
184 |
194 |
30 |
68.5 |
37 |
0,280 |
2400 |
180 |
63 |
| TF180/35 |
35-1 |
266 |
154 |
184 |
194 |
35 |
73.5 |
42 |
0,320 |
2550 |
200 |
65 |
| TF240/20 |
20-1 |
311 |
214 |
244 |
254 |
20 |
58.5 |
25 |
0,190 |
1250 |
125 |
55 |
| TF240/35 |
35-1 |
326 |
214 |
244 |
254 |
35 |
73.5 |
46 |
0,340 |
2500 |
240 |
64 |
| TF270/20 |
20-1 |
341 |
244 |
274 |
284 |
20 |
58.5 |
26 |
0,200 |
1100 |
130 |
53 |
| TF270/35 |
35-1 |
356 |
244 |
274 |
284 |
35 |
73.5 |
49 |
0,350 |
2250 |
260 |
63 |
| TF300/20 |
20-1 |
371 |
274 |
304 |
314 |
20 |
58.5 |
25 |
0,195 |
1200 |
171 |
51 |
| TF300/30 |
30-1 |
381 |
274 |
304 |
314 |
30 |
68.5 |
43 |
0,320 |
1900 |
270 |
61 |
| TF300/40 |
40-1 |
391 |
274 |
304 |
314 |
40 |
78.5 |
53 |
0,400 |
2300 |
330 |
64 |
| TF360/20 |
20-1 |
431 |
334 |
364 |
374 |
20 |
58.5 |
26 |
0,195 |
1050 |
180 |
48 |
| TF360/30 |
30-1 |
441 |
334 |
364 |
374 |
30 |
68.5 |
45 |
0,325 |
1700 |
285 |
60 |
| TF360/40 |
40-1 |
451 |
334 |
364 |
374 |
40 |
78.5 |
55 |
0,450 |
2200 |
370 |
62 |
|
 |
| FF Dimensions: |
 |
 |
 |
| FF Versions: |
 |
| Series |
Motor |
Dimensions |
Input power W |
Input current A |
Free air RPM |
Free air flow rate |
Static pressure PA |
| A |
B |
C |
E |
F |
H |
I |
| FF90/15 |
15-1 |
156 |
64 |
94 |
103 |
112 |
15 |
53.5 |
18 |
0,140 |
1900 |
60 |
60 |
| FF90/20 |
20-1 |
162 |
64 |
94 |
103 |
112 |
20 |
58.5 |
23 |
0,150 |
2400 |
80 |
62 |
| FF120/15 |
15-1 |
186 |
94 |
124 |
133 |
142 |
15 |
53.5 |
19 |
0,160 |
1600 |
85 |
58 |
| FF120/20 |
20-1 |
191 |
94 |
124 |
133 |
142 |
20 |
58.5 |
24 |
0,170 |
2150 |
110 |
62 |
| FF180/15 |
15-1 |
246 |
154 |
184 |
193 |
202 |
15 |
53.5 |
19 |
0,150 |
1300 |
100 |
55 |
| FF180/20 |
20-1 |
251 |
154 |
184 |
193 |
202 |
20 |
58.5 |
25 |
0,180 |
1600 |
125 |
60 |
| FF180/30 |
30-1 |
261 |
154 |
184 |
193 |
202 |
30 |
68.5 |
37 |
0,280 |
2400 |
180 |
63 |
| FF180/35 |
35-1 |
266 |
154 |
184 |
163 |
202 |
202 |
35 |
42 |
0,320 |
2550 |
200 |
65 |
| FF240/20 |
20-1 |
311 |
214 |
244 |
253 |
262 |
20 |
58.5 |
25 |
0,190 |
1250 |
125 |
55 |
| FF240/35 |
35-1 |
326 |
214 |
244 |
253 |
262 |
35 |
73.5 |
46 |
0,340 |
2500 |
240 |
64 |
| FF270/20 |
20-1 |
341 |
244 |
274 |
283 |
292 |
20 |
58.5 |
26 |
0,200 |
1100 |
130 |
53 |
| FF270/35 |
35-1 |
356 |
244 |
274 |
283 |
292 |
35 |
73.5 |
49 |
0,350 |
2250 |
260 |
63 |
| FF300/20 |
20-1 |
371 |
274 |
304 |
313 |
322 |
20 |
58.5 |
25 |
0,195 |
1200 |
171 |
51 |
| FF300/30 |
30-1 |
381 |
274 |
304 |
313 |
322 |
30 |
68.5 |
43 |
0,320 |
1900 |
270 |
61 |
| FF300/40 |
40-1 |
391 |
274 |
304 |
313 |
322 |
40 |
78.5 |
53 |
0,400 |
2300 |
330 |
64 |
| FF360/20 |
20-1 |
431 |
334 |
364 |
373 |
382 |
20 |
58.5 |
26 |
0,195 |
1050 |
180 |
48 |
| FF360/30 |
30-1 |
441 |
334 |
364 |
373 |
382 |
30 |
68.5 |
45 |
0,325 |
1700 |
285 |
60 |
| FF360/40 |
40-1 |
451 |
334 |
364 |
373 |
382 |
40 |
78.5 |
55 |
0,450 |
2200 |
370 |
62 |
|
 |
| Static Pressure Courve: |
 |
 |
 |
 |
 |
 |
| |
| All motors, fans and blowers are manufactured in our factory in Pieve Emanuele (Milano – Italy). Dimensions and specifications can vary. We reserve ourselves the right to make changes anytime we consider it’s the case. |
|
|