TFD/FFD Series
Cross-Flow Fans are particularly indicated for uses where, in limited space, high air volume is required with low noise and regular air-flow.
The FFD series provides an additional fixing option through 4 + 4 extensions placed directly on the side.
23 – 55 W
0,18 – 0,43 A
168 – 382 m3/h
Technical specifications
-
Single phase, 2-shaded poles, impedance protected motor, built according to the CE mark requirements, in compliance with EN 60335-1 standard, with self-aligning and self lubricating sleeve bearings with big oil reservoir.
-
Motor with minimum 130° “B” insulation class.
-
Suitable for continuous operation in ambient temperature from -10 °C to +50 °C.
-
Electrical connection by 6,3 x 0,8 mm, radial or axial, male faston-type connectors, directly fixed on coil.
-
Ø 60 mm aluminum impeller with forward curved constant thickness blades with intermediate reinforcement discs.
-
Housing made of pre-galvanized metal sheet, thanks to the high aeraulic efficiency it guarantees an excellent yield in terms of air flow, static pressure and low noise level.
On request
-
Version with IMQ – CSV approved motor.
-
Motor with different powers and insulation classes: 155° “F” – 180° “H”.
-
Supply voltage from 12V to 400V 50/60 Hz.
-
Version with dual voltage and/or double speed.
-
Electrical connection by means of different cable lengths.
-
Motor coil winding with IP55 protection.
-
Protection against dust and/or humidity.
-
Thermal protector or thermal fuse.
-
Housing with cataphoresis coating.
-
HT versions for operation from -30 °C to +100 °C.
-
Built in compliance with UL – CSA standards.
-
Version fitted with ball bearings.
-
Version built to customers design.
Motor position – Radial Faston
Motor position – Axial Faston
Product Identification Code
TFD | TFD = standard housing. FFD = housing with “ears”. |
180 | Fan blade nominal length: 90 - 120 - 180 - 240 - 270 - 300 - 360 mm. |
35 | Motor stack height: 15 - 20 - 30 - 35 - 40 mm. |
T | Thermal protection: T = thermal protector. F = thermal fuse. Blank = impedance protected. |
1 | Coil winding code. |
R | Electrical connection: R = radial faston-type connectors. A = axial faston-type connectors. C = cables. |
FN | Motor position. |
HT | On request: HT = high-temperature version. IV - IM = low temperature with high relative humidity up to 92%. * INC = coil insulation with IP55 protection. * |
BBBLV | On request: BB = ball bearings on motor. BBBLV = ball bearings on motor and impeller. |
230 | Supply voltage. |
50 | Rated frequency. |
* IV version
Impregnated coil through dip-coating using epoxy transparent paint (standard stator coil dip-coating process).
* IM version
Impregnated coil through dip-coating using transparent epoxy paint with silicone applied on contacts at the end of winding, three-pole wire and coil covered by a nylon cap. The coil is not drowned in the resin but visible; caution should be paid when mounting the motor so that the cap open part faces downward to prevent its filling up with condensate.
* INC version
Coil with IP55 protection, the coil is completely drowned into the epoxy resin.